Removable space maintainers fabricated using a CAD-CAM system for tooth loss: two pediatric case reports

  • Kaori Kohi1
  • Kanae Wada1,*,
  • Yumi Tsuchida2
  • Yumiko Nakashima1
  • Yuika Yamanaka1
  • Tsutomu Iwamoto1

1Department of Pediatric Dentistry/Special Needs Dentistry, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 113-8549 Tokyo, Japan

2Department of Digital Dentistry, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 113-8549 Tokyo, Japan

DOI: 10.22514/jocpd.2026.051 Vol.50,Issue 2,March 2026 pp.217-227

Submitted: 01 August 2025 Accepted: 09 October 2025

Published: 03 March 2026

*Corresponding Author(s): Kanae Wada E-mail: wadadohs@tmd.ac.jp

Abstract

Background: In pediatric dentistry, multiple dental caries, trauma, and congenital anomalies often necessitate prosthetic rehabilitation. A removable space maintainer (RSM) is the only device capable of providing both proximal and vertical retention, serving as an effective prosthetic and functional solution. Advances in digital technology have established computer-aided design/computer-aided manufacturing (CAD-CAM) systems as reliable tools in pediatric dental treatment; however, their application in the fabrication of RSMs and pediatric dentures remains limited. Cases: We describe the cases of two pediatric patients in which RSMs were fabricated using subtractive manufacturing via a CAD-CAM system. The first patient was a boy with partial edentulous mandibular anterior teeth, whereas the other patient was a girl with a missing maxillary right lateral central incisor due to trauma. In both patients, the RSMs were successfully placed without requiring intraoral adjustments, and an excellent fit was achieved. Conclusions: The use of subtractive manufacturing for RSM fabrication offers several advantages, including clinical fit, efficiency, visualization, and esthetics. Nonetheless, further technical refinements are required to enhance fit accuracy.


Keywords

Children; CAD-CAM; Removable space maintainer


Cite and Share

Kaori Kohi,Kanae Wada,Yumi Tsuchida,Yumiko Nakashima,Yuika Yamanaka,Tsutomu Iwamoto. Removable space maintainers fabricated using a CAD-CAM system for tooth loss: two pediatric case reports. Journal of Clinical Pediatric Dentistry. 2026. 50(2);217-227.

References

[1] Shin Y, Wada K, Tsuchida Y, Ijbara M, Ikeda M, Takahashi H, et al. Wear behavior of materials for additive manufacturing after simulated occlusion of deciduous dentition. Journal of the Mechanical Behavior of Biomedical Materials. 2023; 138: 105627.

[2] Huang HY, Yang YT, Chuang CC, Shen YK, Chen MH, Lin WC. Evaluation of the clinical application of personalized 3D printing and CAD/CAM resin crowns to replace stainless steel crowns in paediatric dentistry. International Journal of Paediatric Dentistry. 2024; 34: 811–821.

[3] Gupta G, Gupta DK, Gupta P, Shah P, Khairwa A. Customized zirconia crown in pediatric dentistry from concept to reality. Avicenna Journal of Dental Research. 2023; 15: 27–31.

[4] Tokuc M, Yilmaz H. Comparison of fit accuracy between conventional and CAD/CAM-fabricated band–loop space maintainers. International Journal of Paediatric Dentistry. 2022; 32: 764–771.

[5] Watson L, Danley B, Versluis A, Tantbirojn D, Brooks J, Wells MH. A structural analysis of 3D printed pediatric space maintainers. Pediatric Dentistry. 2023; 45: 342–347.

[6] Cengiz A, Karayilmaz H. Comparative evaluation of the clinical success of 3D-printed space maintainers and band-loop space maintainers. International Journal of Paediatric Dentistry. 2024; 34: 584–592.

[7] Guo H, Wang Y, Zhao Y, Liu H. Computer-aided design of polyetheretherketone for application to removable pediatric space maintainers. BMC Oral Health. 2020; 20: 201.

[8] Priyanka VA, Krishna RL, Nilesh R, Amit J, Aditit T, Ritu K. 3D printed denture for a pediatric patient with complete anodontia: a case report. International Journal of Clinical Dentistry. 2024; 18: 114–118.

[9] Panwar M, Gupta S, Singh U, Das A, Isha S. Role of intraoral scanners in pediatric dentistry. International Journal of Medical and Dental Sciences. 2023; 12: 2071–2076.

[10] Yilmaz H, Aydin MN. Digital versus conventional impression method in children: comfort, preference and time. International Journal of Paediatric Dentistry. 2019; 29: 728–735.

[11] Patel C, Barot GN, Patel MC, Nath KJ, Patel SP, Patel DK. Accuracy and comfort in digital and conventional impression in pediatric dental patients: a randomized comparative study. Cureus. 2025; 17: e76882.

[12] Serrano-Velasco D, Martín-Vacas A, Paz-Cortés MM, Giovannini G, Cintora-López P, Aragoneses JM. Intraoral scanners in children: evaluation of the patient perception, reliability and reproducibility, and chairside time—a systematic review. Frontiers in Pediatrics. 2023; 11: 1213072.

[13] Ozdemir S, Parlakyıldız Gokce A, Unver T. Simulation of three intraoral radiographic techniques in pediatric dental patients: subjective comfort assessment using the VAS and Wong-Baker FACES Pain Raiting Scale. BMC Oral Health. 2020; 20: 33.

[14] Gupta G, Gupta DK, Gupta P, Shah P, Sankhla D, Rana KS. Digital impression and CAD/CAM system applications in pediatric dentistry: case series. International Journal of Research Publication and Reviews. 2023; 7: 197–201.

[15] Teixeira Marques NC, Gurgel CV, Fernandes AP, Lima MC, Machado MA, Soares S, et al. Prosthetic rehabilitation in children: an alternative clinical technique. Case Reports in Dentistry. 2013; 2013: 512951.

[16] Goswami M, Chauhan N. Prosthetic management with removable partial dentures in pediatric dental care: case series. International Journal of Clinical Pediatric Dentistry. 2023; 16: 534–540.

[17] Derbanne MA, Sitbon MC, Landru MM, Naveau A. Case report: early prosthetic treatment in children with ectodermal dysplasia. European Archives of Paediatric Dentistry. 2010; 11: 301–305.