Journal of Clinical Pediatric Dentistry. 2026; 50(5): 118-131. doi: 10.22514/jocpd.2026.121
Original Research

Effect of different setting times of calcium silicate cements on the bond strength to paediatric restorative materials: an in vitro study

Hilal Ecem Keskinkılıç1, İsmail Haktan Çelik1,*,

1Department of Paediatric Dentistry, Faculty of Dentistry, Afyonkarahisar Health Sciences University, 03030 Afyonkarahisar, Turkey

*Corresponding Author(s):haktan.celik@afsu.edu.tr (İsmail Haktan Çelik)

History Submitted: 27 February 2026 | Accepted: 28 April 2026 | Published: 03 September 2026
Copyright:  ©2026 The Author(s). Published by MRE Press.
This is an open access article under the CC BY 4.0 license (https://creativecommons.org/licenses/by/4.0/).

Collapse table of contents

Abstract

Background: This study aimed to evaluate the effect of cement maturation time on shear bond strength (SBS) between three calcium silicate-based cements and paediatric restorative materials. Methods: A total of 405 three-dimensional (3D)-printed resin blocks with standardised cavities (4 mm diameter, 2 mm depth) were filled with Biodentine, NeoMTA 2, or NeoPUTTY. A two-step self-etch adhesive system (Clearfil SE Bond 2) was then applied to the calcium silicate cement surfaces, and Dyract XP, Filtek Z550, or ACTIVA Kids BioACTIVE Restorative was placed after 3 min, 15 min, or 24 h using a Tygon tube with a 2-mm internal diameter to standardise the bonding area. Shear bond strength was measured after 24 h of storage at 37 ℃ and 100% humidity with a crosshead speed of 1 mm/min. Failure modes were examined stereomicroscopically, and selected interfaces were analysed by scanning electron microscopy (SEM). Data were analysed using three-way analysis of variance (ANOVA) with appropriate post hoc tests (α = 0.05). Results: Setting time, cement type, and restorative material significantly affected bond strength (p < 0.001). SBS values ranged from 1.74 ± 0.49 MPa in the NeoPUTTY–Dyract XP group at 3 min to 11.55 ± 2.06 MPa in the Biodentine–ACTIVA Kids BioACTIVE Restorative group at 24 h. Bond strength increased progressively with longer setting times, with the lowest values observed at 3 min and the highest at 24 h. Biodentine generally showed higher bond strength than NeoMTA 2 and NeoPUTTY, while ACTIVA Kids BioACTIVE Restorative generally yielded the highest values among the restorative materials. Failure patterns shifted from predominantly adhesive failures at early time points to more mixed or cohesive failures with longer setting times. Conclusions: Bonding to calcium silicate-based cements is time-dependent. Within the limitations of this in vitro study, bond strength was influenced by setting time, cement type, and restorative material type.

Keywords:Calcium silicate-based cements;Shear bond strength;Biodentine;NeoMTA 2;ACTIVA Kids BioACTIVE Restorative
PDF(6.16 MB)|EndNote (RIS)|BibTeX|RefMan|RefWorks

Cite this article

Hilal Ecem Keskinkılıç, İsmail Haktan Çelik. Effect of different setting times of calcium silicate cements on the bond strength to paediatric restorative materials: an in vitro study. Journal of Clinical Pediatric Dentistry. 2026; 50(5): 118-131. doi: 10.22514/jocpd.2026.121

1. Introduction

Vital pulp therapies (VPTs) represent key biologically based approaches in paediatric dentistry for preserving the vitality of primary and immature permanent teeth. These treatments support pulp tissue healing, maintain tooth function, and, especially in young permanent teeth, allow continued root development [1].

Calcium silicate-based cements (CSCs) are among the most commonly used biomaterials in VPT. Mineral trioxide aggregate (MTA), a well-established CSC, has long been regarded as the “gold standard” because of its sealing ability, antibacterial properties, and potential to induce hard tissue formation [2, 3]. However, conventional MTA has disadvantages that may limit its clinical use, including handling difficulty, risk of discoloration, and prolonged setting time [2]. A prolonged setting time may delay placement of the definitive restoration, require an additional appointment, and increase the risk of contamination and microleakage, thereby adversely affecting the success of VPT outcomes [4, 5].

To overcome these disadvantages, new-generation CSC systems have been developed. In this context, Biodentine (Septodont, France) has a wide range of indications due to its short setting time and favorable mechanical properties [6]. NeoPUTTY, developed by NuSmile (Houston, USA), is a premixed formulation, while NeoMTA 2 offers ease of use in clinical practice due to its optimized handling characteristics. These next-generation biomaterials represent contemporary and effective options, with reduced setting times and a lower risk of discoloration [7].

The long-term clinical success of VPT depends not only on the biological properties of the pulp-capping material but also on the quality of the interfacial bond formed with the definitive restorative material placed over it [8]. However, the mismatch between the hydrophilic nature and ongoing hydration of CSCs and the hydrophobic character of resin-based restorative materials may compromise interfacial bond strength [9]. The optimal adhesive protocol for bonding to CSCs remains a subject of debate [9, 10, 11]. In this context, both total-etch and self-etch strategies have been discussed in the literature. Although phosphoric acid etching used in total-etch systems may enhance micromechanical retention, it has also been reported to adversely affect the surface integrity of CSCs during early setting periods [12]. Therefore, self-etch adhesive systems are often preferred to preserve the surface characteristics of the bioceramic matrix. In addition to micromechanical retention, functional monomers such as 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) in some self-etch systems may contribute to interfacial stability through potential chemical interaction with calcium ions released from CSC surfaces [10, 11].

In paediatric dentistry, the choice of coronal restorative materials is made considering isolation conditions, patient compliance, and material-related mechanical properties. In this context, compomers such as Dyract XP are frequently preferred because of their fluoride release and ease of application, whereas nanohybrid composites such as Filtek Z550 are commonly chosen for their mechanical strength and aesthetic performance [13, 14]. In recent years, ACTIVA Kids BioACTIVE Restorative, described as a “bioactive” material, has attracted attention due to its potential to promote remineralisation [15]. One of the debated issues in clinical protocols is the timing of the definitive restoration following placement of the biomaterial. This issue is particularly relevant in paediatric patients, for whom limited cooperation may often necessitate completing treatment in a single visit. Although previous studies have investigated the bond strength of various restorative systems to CSCs, most have focused on later maturation stages, such as 24 h and beyond, when the material has largely completed its hydration process [8, 9]. However, data on the bonding performance of bioceramics such as NeoMTA 2 and premixed NeoPUTTY at the clinically relevant time points of 3 and 15 min remain limited [16, 17, 18]. Furthermore, the interaction between ACTIVA Kids BioACTIVE Restorative, a material characterized by bioactive properties and ion release, and the dynamic hydration process of these bioceramics has not yet been investigated, particularly during the critical initial 15 min period.

Therefore, this study aimed to evaluate, under in vitro conditions, the shear bond strength between three different calcium silicate-based cements (Biodentine, NeoMTA 2, and NeoPUTTY) and three paediatric restorative materials (Dyract XP, Filtek Z550, and ACTIVA Kids BioACTIVE Restorative) applied after different setting periods of 3 min, 15 min, and 24 h. The null hypothesis of the study was that there would be no statistically significant differences in shear bond strength values across setting time, cement type, and restorative material type.

2. Materials and methods

Ethical approval for this in vitro study was granted by the Afyonkarahisar Health Sciences University Non-Interventional Scientific Research Ethics Committee (Approval No: 2025/389). Sample size calculation was performed using G*Power software version 3.1.9.7 (Heinrich Heine University Düsseldorf, Düsseldorf, NRW, Germany), based on a similar reference study [19]. An a priori power analysis was conducted within the F-test family using the procedure for the planned full 3 × 3 × 3 factorial ANOVA design. Assuming an effect size of f = 0.25, a significance level of α = 0.05, and a power of 0.80, the minimum required sample size was determined to be 249 specimens. To compensate for possible technical losses, this number was increased by 50%, and the study was completed with a total of 405 specimens. Based on the final sample size, the achieved power of the study was 0.967. All experimental procedures were performed by a single operator (HEK). The materials used are presented in Table 1, and the study workflow is illustrated in Fig. 1.

Table 1.Commercial names and lot numbers, type/form, components, colour, manufacturer, and instructions for use of the materials used in the study.
Commercial names and lot numbersType/FormComponentsManufacturerInstructions for use
NeoMTA 2
Lot number: 2025031401
Calcium silicate-based root and pulp treatment cement/Powder–liquid gelPowder: Tricalcium/dicalcium silicate, calcium oxide, tantalum oxide, and auxiliary metal oxides (Al2O3, MgO, Fe2O3, SiO2), tricalcium aluminate. Liquid: Polymer-based carrier gel containing Ca2+Avalon Biomed Houston, TX, USA1. Dispense 1 scoop (0.05 g or 0.1 g) of NeoMTA powder onto a glass slab or a non-absorbent pad.
2. Dispense one drop of NeoMTA Gel next to the powder.
3. Gradually add the gel to the powder. Mix by pressing the powder/gel mixture firmly against the glass slab, ensuring all powder is thoroughly wetted, and continue mixing until a putty consistency is achieved.
Biodentine
Lot number: B32664B
Calcium silicate-based cement/Capsule: powder–liquid systemPowder: Tricalcium/dicalcium silicate, calcium carbonate, zirconium oxide, calcium oxide, iron oxide. Liquid: Soluble polymer–water system containing CaCl2Septodont; Saint-Maur-des-Fossés, France1. Open the capsule and place it in the white capsule holder.
2. Detach the single-dose liquid container and tap the closed cap to ensure all liquid is inside. Add 5 drops from the container into the capsule.
3. Close the capsule. Place it in a mixing device operating at a 4000–4200 rpm and mix for 30 seconds.
Dyract XP
Lot number: 2507000820
Polyacid-modified composite resinUDMA, TEGDMA, TMPTMA-based dimethacrylate resins, camphorquinone, amine co-initiator, BHT and UV stabiliser, Sr-alumino-fluoro-silicate glass, SiO2, SrF, Fe2O3, and TiO2Dentsply Sirona; Konstanz, Germany1. Place the compule into the Compule Gun.
2. Remove the coloured cap. The compule can rotate 360° to ensure the correct entry angle into the cavity or onto the mixing pad.
3. Cure each layer using a suitable light-curing unit. For 2 mm thick increments, a polymerisation time of 10 seconds is recommended when using a light source with an output ≥500 mW/cm2.
Filtek Z550
Lot number: 11225283
Nanohybrid composite resinBis-GMA/UDMA/Bis-EMA/TEGDMA/PEGDMA matrix + ZrO2–SiO2 filler + photoinitiator system + TiO2–Fe2O3 pigments3M ESPE; St. Paul, MN, USAAccording to the manufacturer’s instructions, the shade A2 restorative material is applied in 2.0 mm increments; and polymerization for 20 seconds is recommended with a light source of minimum 400 mW/cm2 intensity, or for 10 seconds with a minimum intensity of 1000 mW/cm2.
ACTIVA Kids BioACTIVE Restorative
Lot number: 231231
Bioactive composite resinDiurethane/polyacrylic acid-modified methacrylates, amorphous silica, NaF, and waterPulpdent Corporation; Watertown, MA, USA1. Place the ACTIVA tip into the preparation and allow the material to flow slowly. Keep the tip immersed in the material while moving it. Allow time for ionic activity to interact, integrate, and form chemical bonds with the dentine. Ensure no air bubbles remain.
2. Apply in increments ≤4 mm and polymerise for 20 seconds using a LED light-curing unit with an intensity ≥1000 mW/cm2.
Clearfil SE Bond 2
Lot number: 000502
Two-step self-etch adhesive systemPrimer: 10-MDP, HEMA, hydrophilic dimethacrylates, photoinitiator, and water.
Adhesive: 10-MDP, HEMA, Bis-GMA, hydrophilic dimethacrylates, CQ, silanated colloidal silica, and initiator system
Kuraray Noritake Dental Inc.; Okayama, Japan1. Apply the primer to the surface for 20 seconds.
2. Dry with mild air for 5 seconds.
3. After applying the adhesive, thin it with mild air for 5 seconds.
4. Light-cure for 10 seconds.
Al2O3, aluminium oxide; MgO, magnesium oxide; Fe2O3, iron oxide; SiO2, silicon dioxide; Ca2+, calcium ion; CaCl2, calcium chloride; UDMA, urethane dimethacrylate; TEGDMA, triethylene glycol dimethacrylate; TMPTMA, trimethylolpropane trimethacrylate; BHT, butylated hydroxytoluene; UV, ultraviolet; SrF, strontium fluoride; TiO2, titanium dioxide; Bis-GMA, bisphenol A-glycidyl methacrylate; Bis-EMA, bisphenol A ethoxylated dimethacrylate; PEGDMA, polyethylene glycol dimethacrylate; ZrO2, zirconium dioxide; NaF, sodium fluoride; LED, light-emitting diode; 10-MDP, 10-methacryloyloxydecyl dihydrogen phosphate; HEMA, 2-hydroxyethyl methacrylate; CQ, camphorquinone; rpm, revolutions per minute.
Study workflow and experimental design.

Fig. 1.Study workflow and experimental design.

2.1 Specimen preparation

To ensure standardised positioning of specimens within the universal testing machine (MOD Dental MIC-101, Esetron Smart Robotechnologies, Ankara, Turkey), 405 cylindrical resin blocks with a diameter of 15 mm and a length of 130 mm, featuring a central cavity measuring 4 mm in diameter and 2 mm in depth, were fabricated using a 3D printer (Sonic Mini 8K, Phrozen, Hsinchu City, Taiwan) and a polymethyl methacrylate (PMMA)-based 3D printing resin (NextDent, 3D Systems, Soesterberg, The Netherlands). To equilibrate moisture content and standardize initial conditions across all specimens, the resin blocks were stored in an incubator at 37 ℃ and 100% humidity for 24 h before the application of CSCs.

The resin blocks were randomly and equally divided into three main groups (n = 135 per group), according to the CSC applied: NeoPUTTY® MTA, NeoMTA® 2, and Biodentine™. The calcium silicate-based materials were prepared in accordance with the manufacturers’ instructions, as specified in Table 1, and condensed into the cavities. To ensure surface standardization and obtain a flat material surface, a glass slab was placed over the materials. The procedures related to the setting times and restorative application stages are detailed below.

2.2 Waiting-time protocol (3 min, 15 min, 24 h)

Following the placement of CSCs, the specimens were divided into three subgroups according to restorative application intervals of 3 min, 15 min, and 24 h. During the setting period, a moist cotton pellet was placed on the material surface of all specimens, and the specimens were stored at 37 ℃ and 100% humidity. At the end of the duration, the cotton pellet was removed, and restorative procedures were initiated.

2.3 Preparation of restorative materials

A two-step self-etch adhesive system (Clearfil SE™ Bond 2, Kuraray Noritake Dental Inc., Okayama, Japan) was applied to the CSC surface, restricted to the bonding area designed for restorative material application, according to the manufacturer’s instructions (Table 1). The adhesive material was polymerised using a light-emitting diode (LED) light-curing unit (VALO™, Ultradent Products Inc., South Jordan, UT, USA) in standard mode at 1000 mW/cm2. A flexible transparent polymer tube (Tygon® S3 E-3603, Product Code: ACF1S1502, Saint-Gobain Performance Plastics, Charny, France; distributed by Interlab AS, Istanbul, Turkey) with an internal diameter of 2 mm, an external diameter of 4 mm, and a height of 2 mm was used to standardize the bonding area.

2.4 Application of the restorative materials

All restorative materials used in the study, including Dyract XP, Filtek Z550, and ACTIVA Kids BioACTIVE Restorative, were carefully placed into the tubes to prevent air-bubble formation. Dyract XP and ACTIVA Kids BioACTIVE Restorative were applied using their manufacturer-specific application guns with mixing tips, whereas Filtek Z550 nanohybrid composite was placed using a hand instrument. All restorative materials were polymerised using the same LED light-curing unit (VALO™, Ultradent Products Inc., South Jordan, UT, USA) according to the manufacturer’s instructions (Table 1). Following polymerization, all specimens were incubated at 37 ℃ and 100% humidity for 24 h. After the storage period, the tubes were carefully removed using a sharp scalpel.

2.5 Shear bond strength testing

The specimens were placed in a universal testing machine (MOD Dental MIC-101, Esetron Smart Robotechnologies, Ankara, Türkiye) to determine shear bond strength. A shear load was applied at a crosshead speed of 1 mm/min until failure using a knife-edged apparatus positioned parallel to the interface adjacent to the base of the restorative cylinder (Fig. 2). The measured force values were recorded in Newtons (N). Because the bonding area was standardised using a Tygon tube with an internal diameter of 2 mm, the bonding area was calculated as 3.14 mm2 (πr2 with a radius of 1 mm), and the bond strength values were expressed in megapascals (MPa) by dividing the force values by this area.

Shear bond strength test set-up.

Fig. 2.Shear bond strength test set-up.

2.6 Failure mode analysis

Following shear bond strength (SBS) testing, the fractured surfaces of all specimens were examined using an operating microscope (Zumax® OMS 3200 PRO, Zumax Medical Co., Ltd., Suzhou, China) at ×24 magnification. Failure modes were evaluated by two blinded researchers (İHÇ, HEK), and inter-observer agreement was assessed using Cohen’s kappa coefficient. Failure modes were classified as adhesive failure, cohesive failure within the CSC, cohesive failure within the restorative material, and mixed failure.

2.7 Scanning electron microscopy (SEM) analysis

A total of 27 specimens were subjected to SEM analysis, with one representative specimen selected from each experimental subgroup. The selected specimens were those that best represented the predominant failure pattern in their respective groups. The specimens were mounted on aluminum stubs using adhesive tape and coated with 5 nm of gold in a LEO 1430 VP scanning electron microscope (Carl Zeiss, Oberkochen, BW, Germany). A single operator scanned the entire specimen surface and evaluated the samples at an accelerating voltage of 15 kV and ×1000 magnification.

2.8 Statistical analysis

Data were analysed using SPSS version 22.0 (IBM SPSS Statistics; IBM Corp., Armonk, NY, USA). Normality was assessed using the Kolmogorov-Smirnov test, and homogeneity of variances was evaluated using the Levene test. The main effects of time, cement type, and restorative material, as well as their interactions, were analyzed using three-way ANOVA. For significant results, simple-effects analyses were performed, and pairwise comparisons were conducted using Tukey honestly significant difference (HSD) or Games-Howell tests, depending on variance homogeneity. The significance level was set at p < 0.05.

3. Results

According to the three-way ANOVA results, the main effects of setting time, cement type, and restorative material on bond strength were statistically significant (p < 0.001). The three-way interaction (Time × Cement × Restorative material) was not statistically significant (p = 0.054); however, all two-way interaction effects were statistically significant (Time × Cement: p = 0.038; Time × Restorative material: p < 0.001; Cement × Restorative material: p = 0.009) (Table 2). Comparisons related to these two-way interactions are presented in Tables 3 and 4.

Table 2.Effects of setting time, cement type, and restorative material on bond strength.
EffectType III SSdfMean SquareFp
Time2667.66821333.834853.518<0.001
Cement197.902298.95163.319<0.001
Restorative material391.2662195.633125.185<0.001
Time × Cement16.03944.0102.5660.038
Time × Restorative material186.695446.67429.867<0.001
Cement × Restorative material21.52145.3803.4430.009
Time × Cement × Restorative material24.13283.0171.9300.054
SS, sum of squares; df, degrees of freedom; MS, mean square. p-values were obtained from three-way ANOVA (Type III SS). Statistical significance was set at p < 0.05.
Table 3.Time-dependent changes in bond strength for each CSC according to restorative material.
Restorative MaterialCSCTime
3 min (Mean ± SD)15 min (Mean ± SD)24 h (Mean ± SD)
Dyract XP
NeoPUTTY1.74 ± 0.49Aa3.10 ± 0.65Ab5.53 ± 0.72Ac
NeoMTA 21.80 ± 0.65Aa2.94 ± 1.53Ab5.33 ± 1.15Ac
Biodentine2.16 ± 0.95Aa4.17 ± 1.68Ab6.84 ± 1.84Ac
p0.7320.1080.018
Filtek Z550
NeoPUTTY1.83 ± 0.57Aa3.73 ± 0.93Ab8.06 ± 0.94Ac
NeoMTA 21.92 ± 0.72Aa3.78 ± 0.81Ab9.65 ± 1.68Bc
Biodentine3.71 ± 0.85Ba4.46 ± 1.44Aa10.57 ± 1.54Bb
p<0.0010.423<0.001
ACTIVA Kids BioACTIVE Restorative
NeoPUTTY2.30 ± 0.63Aa4.30 ± 1.12Ab8.81 ± 1.33Ac
NeoMTA 22.40 ± 0.47Aa4.55 ± 1.38Ab10.35 ± 2.08ABc
Biodentine3.77 ± 1.08Ba6.88 ± 1.82Bb11.55 ± 2.06Bc
p<0.001<0.0010.003
Data are presented as mean ± standard deviation (SD). p: The p-value is the one-way ANOVA p-value for the overall comparison between groups at each point. Different uppercase letters in the same column indicate statistical differences between CSCs, and different lowercase letters in the same row indicate statistical differences between time points (p < 0.05). Tukey HSD or Games-Howell post-hoc tests were used for pairwise comparisons. Bond strength is expressed in MPa. CSC, Calcium silicate-based cement.
Table 4.Time-dependent changes in bond strength for each restorative material according to cement type.
CSCRestorative MaterialTime
3 min (Mean ± SD)15 min (Mean ± SD)24 h (Mean ± SD)
NeoPUTTY
Dyract XP1.74 ± 0.49Aa3.10 ± 0.65Ab5.53 ± 0.72Ac
Filtek Z5501.83 ± 0.57Aa3.73 ± 0.93ABb8.06 ± 0.94Bc
ACTIVA Kids BioACTIVE Restorative2.30 ± 0.63Aa4.30 ± 1.12Bb8.81 ± 1.33Bc
p0.0660.012<0.001
NeoMTA 2
Dyract XP1.80 ± 0.65Aa2.94 ± 1.53Ab5.33 ± 1.15Ac
Filtek Z5501.92 ± 0.72Aa3.78 ± 0.81ABb9.65 ± 1.68Bc
ACTIVA Kids BioACTIVE Restorative2.40 ± 0.47Aa4.55 ± 1.38Bb10.35 ± 2.08Bc
p0.0870.015<0.001
Biodentine
Dyract XP2.16 ± 0.95Aa4.17 ± 1.68Ab6.84 ± 1.84Ac
Filtek Z5503.71 ± 0.85Ba4.46 ± 1.44Aa10.57 ± 1.54Bb
ACTIVA Kids BioACTIVE Restorative3.77 ± 1.08Ba6.88 ± 1.82Bb11.55 ± 2.06Bc
p<0.001<0.001<0.001
Data are presented as mean ± standard deviation (SD). p: The p-value is the one-way ANOVA p-value for the overall comparison between groups at each point. Different uppercase letters in the same column indicate a statistically significant difference between restorative materials, and different lowercase letters in the same row indicate a statistically significant difference between time points (p < 0.05). Tukey HSD or Games-Howell post-hoc tests were used for pairwise comparisons. Bond strength is expressed in MPa. CSC, Calcium silicate-based cement.

In the Dyract XP group, bond strength varied significantly among cement types at 24 h (p = 0.018); however, post-hoc analyses revealed no significant pairwise differences between the cement groups. In the Filtek Z550 group, significant differences were identified among the cements at the 3 min and 24 h time points (p < 0.001), with the highest bond strength observed in the Biodentine group and the lowest values in the NeoPUTTY group at both time points. In the ACTIVA Kids BioACTIVE Restorative group, significant differences were found among the cements at all time points (p < 0.05). Regarding the effect of setting time, bond strength increased significantly with increasing setting time across all restorative material and cement groups; the lowest values were obtained at 3 min, and the highest values were recorded at 24 h (p < 0.001) (Table 3).

In the NeoPUTTY and NeoMTA 2 groups, the restorative material type significantly influenced bond strength at the 15 min and 24 h intervals (p < 0.05). In both cement groups, the highest bond strength was achieved with ACTIVA Kids BioACTIVE Restorative, whereas the lowest values were recorded in the Dyract XP group. Specifically, at 24 h, Dyract XP demonstrated significantly lower bond strength compared to Filtek Z550 and ACTIVA Kids BioACTIVE Restorative (p < 0.001). In the Biodentine group, bond strength exhibited significant differences among restorative materials at all time points (p < 0.001), with ACTIVA Kids BioACTIVE Restorative yielding the highest values and Dyract XP yielding the lowest values across all measurements. Regarding the effect of setting time, bond strength increased significantly across all cement–restorative material combinations as the setting time increased; the lowest values were obtained at 3 min, and the highest values were recorded at 24 h (p < 0.001) (Table 4).

Inter-observer agreement for the failure mode evaluation was high (Cohen’s kappa = 0.87). No cohesive failure within the restorative material was observed in any group or at any time point. Adhesive failures predominated at 3 min; however, their frequency decreased at 15 min, accompanied by increases in cohesive failures within the CSC and Mixed failures. By 24 h, adhesive failures declined to their lowest level, and the majority of failures consisted of cohesive failures within the CSC and mixed failures (Table 5). Representative operating microscopic images of the observed failure modes are presented in Fig. 3, and SEM images of representative fracture surfaces are presented in Fig. 4.

Table 5.Fracture types in different groups.
CSCTimeRestorative MaterialFracture Types
AdhesiveCohesive failure within the restorative materialCohesive failure within the CSCMixed
NeoPUTTY
3 minDyract XP13002
Filtek Z55012012
ACTIVA Kids BioACTIVE Restorative11013
15 minDyract XP9024
Filtek Z5508034
ACTIVA Kids BioACTIVE Restorative8025
24 hDyract XP4065
Filtek Z5503084
ACTIVA Kids BioACTIVE Restorative2085
NeoMTA 2
3 minDyract XP12012
Filtek Z55011013
ACTIVA Kids BioACTIVE Restorative10023
15 minDyract XP6027
Filtek Z5505037
ACTIVA Kids BioACTIVE Restorative4038
24 hDyract XP3084
Filtek Z55020103
ACTIVA Kids BioACTIVE Restorative10113
Biodentine
3 minDyract XP8025
Filtek Z5509024
ACTIVA Kids BioACTIVE Restorative8034
15 minDyract XP5046
Filtek Z5504056
ACTIVA Kids BioACTIVE Restorative3048
24 hDyract XP3093
Filtek Z55020112
ACTIVA Kids BioACTIVE Restorative10122
CSC, Calcium silicate-based cement.
Representative operating microscopic images of failure modes 
after SBS testing. (A) Adhesive failure. (B) Cohesive failure within the calcium 
silicate cement. (C) Mixed failure.

Fig. 3.Representative operating microscopic images of failure modes after SBS testing. (A) Adhesive failure. (B) Cohesive failure within the calcium silicate cement. (C) Mixed failure.

SEM images of fracture surfaces after SBS testing. (A) Dyract XP 
+ NeoPUTTY, 3 min; (B) Filtek Z550 + NeoPUTTY, 3 min; (C) ACTIVA Kids BioACTIVE 
Restorative + NeoPUTTY, 3 min; (D) Dyract XP + NeoMTA 2, 3 min; (E) Filtek Z550 + 
NeoMTA 2, 3 min; (F) ACTIVA Kids BioACTIVE Restorative + NeoMTA 2, 3 min; (G) 
Dyract XP + Biodentine, 3 min; (H) Filtek Z550 + Biodentine, 3 min; (I) ACTIVA 
Kids BioACTIVE Restorative + Biodentine, 3 min; (J) Dyract XP + NeoPUTTY, 15 min; 
(K) Filtek Z550 + NeoPUTTY, 15 min; (L) ACTIVA Kids BioACTIVE Restorative + 
NeoPUTTY, 15 min; (M) Dyract XP + NeoMTA 2, 15 min; (N) Filtek Z550 + NeoMTA 2, 
15 min; (O) ACTIVA Kids BioACTIVE Restorative + NeoMTA 2, 15 min; (P) Dyract XP + 
Biodentine, 15 min; (Q) Filtek Z550 + Biodentine, 15 min; (R) ACTIVA Kids 
BioACTIVE Restorative + Biodentine, 15 min; (S) Dyract XP + NeoPUTTY, 24 h; (T) 
Filtek Z550 + NeoPUTTY, 24 h; (U) ACTIVA Kids BioACTIVE Restorative + NeoPUTTY, 
24 h; (V) Dyract XP + NeoMTA 2, 24 h; (W) Filtek Z550 + NeoMTA 2, 24 h; (X) 
ACTIVA Kids BioACTIVE Restorative + NeoMTA 2, 24 h; (Y) Dyract XP + Biodentine, 
24 h; (Z) Filtek Z550 + Biodentine, 24 h; (Aa) ACTIVA Kids BioACTIVE Restorative 
+ Biodentine, 24 h.

Fig. 4.SEM images of fracture surfaces after SBS testing. (A) Dyract XP + NeoPUTTY, 3 min; (B) Filtek Z550 + NeoPUTTY, 3 min; (C) ACTIVA Kids BioACTIVE Restorative + NeoPUTTY, 3 min; (D) Dyract XP + NeoMTA 2, 3 min; (E) Filtek Z550 + NeoMTA 2, 3 min; (F) ACTIVA Kids BioACTIVE Restorative + NeoMTA 2, 3 min; (G) Dyract XP + Biodentine, 3 min; (H) Filtek Z550 + Biodentine, 3 min; (I) ACTIVA Kids BioACTIVE Restorative + Biodentine, 3 min; (J) Dyract XP + NeoPUTTY, 15 min; (K) Filtek Z550 + NeoPUTTY, 15 min; (L) ACTIVA Kids BioACTIVE Restorative + NeoPUTTY, 15 min; (M) Dyract XP + NeoMTA 2, 15 min; (N) Filtek Z550 + NeoMTA 2, 15 min; (O) ACTIVA Kids BioACTIVE Restorative + NeoMTA 2, 15 min; (P) Dyract XP + Biodentine, 15 min; (Q) Filtek Z550 + Biodentine, 15 min; (R) ACTIVA Kids BioACTIVE Restorative + Biodentine, 15 min; (S) Dyract XP + NeoPUTTY, 24 h; (T) Filtek Z550 + NeoPUTTY, 24 h; (U) ACTIVA Kids BioACTIVE Restorative + NeoPUTTY, 24 h; (V) Dyract XP + NeoMTA 2, 24 h; (W) Filtek Z550 + NeoMTA 2, 24 h; (X) ACTIVA Kids BioACTIVE Restorative + NeoMTA 2, 24 h; (Y) Dyract XP + Biodentine, 24 h; (Z) Filtek Z550 + Biodentine, 24 h; (Aa) ACTIVA Kids BioACTIVE Restorative + Biodentine, 24 h.

4. Discussion

Because CSCs continue to undergo setting and maturation after placement, the bond formed over them may be influenced by the timing of the restorative application. Therefore, bond quality depends not only on the restorative material used but also on the stage of cement maturation at the time of restoration. In the present study, the null hypothesis was rejected, as SBS was significantly affected by setting time, cement type, and restorative material type. This finding is particularly important in paediatric dentistry, where the timing of restorative treatment is often determined by clinical conditions.

In clinical practice, treatment must often be completed in a single visit due to limited patient cooperation in paediatric populations [20]. Therefore, the 3 min and 15 min intervals were selected in the present study to simulate a single-visit clinical approach, whereas 24 h was included as a commonly used reference time point in the literature. In addition, because acid etching may adversely affect the surface integrity of immature CSC, a two-step self-etch adhesive containing 10-MDP (Clearfil SE Bond 2) was preferred to avoid aggressive surface alteration during early maturation while maintaining a standardized bonding protocol [10, 11, 12].

In the dental literature, both macro-scale tests (e.g., SBS and tensile bond strength (TBS)), and micro-scale (e.g., μSBS, μTBS) bond strength tests are commonly used to evaluate the bond strength. Although micro-tests provide measurements from limited bonding areas, they have disadvantages related to technique sensitivity during specimen preparation and a high risk of pre-test failure [21]. The low cohesive strength and structural heterogeneity of CSCs during the early setting phase may compromise specimen integrity in μTBS tests. Therefore, the SBS test was selected in the present study to ensure higher reproducibility and methodological standardization.

Standardized 3D-printed resin blocks were used in this study to reduce the anatomical variability inherent in natural teeth and to ensure uniform specimen geometry across all groups. Although natural tooth tissues provide the most clinically relevant substrate, structural differences such as tubule density and mineral content may influence bond strength measurements. Therefore, a standardized 3D-printed model was preferred to provide more controlled conditions for evaluating the effects of setting time and material combinations on bond strength.

Adequate bonding of the restorative material to the bioceramic cement is essential for maintaining a long-term seal and minimising microleakage. Although no definitive threshold for bond strength exists in the literature, clinically acceptable values have been reported to be approximately 9–12 MPa, whereas values of 17–20 MPa may be required to maintain interfacial integrity against polymerization shrinkage stresses [18, 22]. However, these values should be interpreted as approximate reference ranges rather than absolute thresholds, particularly for calcium silicate-based cements. In the present study, mean SBS values were generally observed to remain below these reference ranges, even in the 24 h delayed restoration groups.

In the present study, bond strength increased with longer waiting times across all cement-restorative material combinations, with the lowest values at 3 min and the highest values at 24 h. This pattern may be explained by progressive maturation of CSCs, as the initially porous and mechanically weak surface becomes more cohesive over time [23]. The accompanying shift in failure mode distribution, from predominantly adhesive failures at 3 min toward more cohesive and mixed failures at later time points, further supports the development of a more stable bonding interface as cement maturation proceeds.

The present findings are largely consistent with the literature. Previous studies have reported that delayed restoration protocols over Biodentine exhibit higher SBS values compared to early-stage applications [10]. Similarly, for NeoMTA 2 and NeoPUTTY materials, delayed restorations (7 days) have been reported to significantly improve bonding performance compared to early-stage applications (14 min) [18]. Conversely, several studies have reported that the setting time does not result in statistically significant differences in bond strength [16, 24].

The findings of the present study are partially consistent with those of Celiksoz and Irmak (2024), who reported significantly lower bond strength values at 3 min for Biodentine and RetroMTA [16]. However, while their study demonstrated similar bonding effectiveness at 12 min and 24 h, a continuous increase in SBS was observed in the present study as maturation progressed toward 24 h. This discrepancy may be attributed to methodological differences, including the variations in the restorative material sets used and the selection of a 15 min interval instead of 12 min.

Similarly, immediate and 7-day delayed restorations were compared using Biodentine, TotalFill BC Putty, and an experimental bioactive cement named pulp capping material (PCM; Coltène/Whaledent, Altstätten, Switzerland), and no significant difference was reported between immediate and delayed groups when restorations were performed using Clearfil SE Bond and SDR [24].

In the present study, CSC type influenced bond strength, with the highest mean SBS values observed in the Biodentine group, followed by NeoMTA 2 and NeoPUTTY. This pattern may be related to the presence of calcium chloride in the Biodentine liquid, which may accelerate hydration and promote earlier surface stabilization. As a result, the adhesive system may interact with a more mechanically stable surface even at an early stage. In contrast, premixed materials such as NeoPUTTY, which rely largely on environmental moisture for setting, may exhibit lower early cohesive strength and more variable surface properties, contributing to the lower SBS values [25].

Several studies have reported that Biodentine may exhibit higher bond strength compared to other CSCs. For example, in a study evaluating the bonding of different bioceramics to dual-cure composite, Biodentine yielded higher SBS values than NeoMTA [26]. Similarly, a recent study indicated that Biodentine demonstrated higher bonding performance compared to NeoMTA Plus, and that surface preparation methods significantly influenced bond strength [27]. However, other studies suggest that the cement type may not have a decisive effect on bond strength. A study published in 2023 evaluating the μSBS of various CSCs to bulk-fill composite reported no significant difference between Biodentine and NeoMTA 2 [28]. This finding contrasts with the higher SBS values observed in the Biodentine group in the present study. This discrepancy may be attributed to differences between μSBS and SBS testing methods, particularly regarding bonding area and stress distribution, as well as differences in adhesive strategies and surface preparation protocols. Furthermore, evaluation of early time points (3 and 15 min) using Clearfil SE Bond 2 may have enhanced the detection of differences related to initial surface stability and setting kinetics.

Another in vitro study comparing self-adhering flowable composite and bulk-fill flowable composite on various pulp capping materials reported the highest SBS value for the NeoMTA Plus and SDR combination [29]. This result suggests that bonding performance may depend significantly not only on the cement type but also on the restorative material type and the adhesive strategy employed. The improved management of polymerisation stress by bulk-fill materials such as SDR, along with the protocol-related difference, may explain the favourable outcome observed for NeoMTA Plus. In contrast, the present study used Clearfil SE Bond 2 and evaluated early time points, which may have increased sensitivity to the initial surface characteristics of the cements.

In the present study, restorative material type was a determinant of bond strength to CSCs. A consistent ranking was observed across all time intervals; the highest mean SBS values were obtained in the ACTIVA Kids BioACTIVE Restorative group, followed by Filtek Z550 and Dyract XP, respectively. The higher bond strength values observed with ACTIVA Kids BioACTIVE Restorative across all time intervals may be attributed to the hybrid structure of the material and its potential chemical affinity with bioceramics [30]. While the hydrophilic nature of CSCs and high surface moisture during the early hydration phase restricts the bonding of traditional hydrophobic restorative material, the moisture-tolerant bioactive matrix of ACTIVA Kids BioACTIVE Restorative provides more effective interfacial wettability.

It is speculated that ionic interaction between the acid-modified methacrylates in the restorative material and free Ca2+ ions released from the CSC surface may contribute to chemical integration alongside micromechanical retention. This mechanism may enhance interfacial stability; however, further chemical analyses are required to confirm this mechanism.

Composite resins with higher resin content are known to demonstrate improved compatibility with adhesive systems and enhanced interfacial stability [31]. Nevertheless, their chemical interaction potential with CSCs remains more limited compared to that of bioactive hybrid restorative materials, which may explain the lower SBS values compared with ACTIVA Kids BioACTIVE Restorative. Similarly, compomers have been reported to possess lower resin content and reduced wettability properties, which may negatively affect interfacial stability by limiting effective mechanical and chemical interaction with CSCs [13].

The present study findings are consistent with several previous studies. For example, in a study conducted on ProROOT MTA, ion-releasing materials such as Cention N and ACTIVA Kids BioACTIVE Restorative demonstrated higher SBS than compomers [32]. Similarly, bioactive materials have been reported to show high bonding performance with CSCs, even under different experimental protocols and Activa formulations (ACTIVA BioACTIVE Restorative) [19]. Furthermore, composite resin restorations applied to Biodentine have been reported to produce stronger and more stable bonds than compomers and some other restorative materials [33], possibly due to improved adhesive infiltration into surface microporosities and formation of a more homogeneous hybrid layer.

However, some studies report findings that contrast with the present results. Certain investigations have shown that ACTIVA BioACTIVE Restorative exhibited significantly lower bonding performance than that of the composite resin groups [27]. This difference may be explained by protocol-related differences, including the use of total-etch adhesive systems, which may alter the surface chemistry of CSCs following acid application. The 10-MDP-containing self-etch approach used in the present study may have preserved surface integrity more effectively, thereby improving bonding performance. Furthermore, some studies have reported no statistically significant differences between composite resin and compomer restorations bonded to white MTA [34]. These differences may be related to variations in adhesive generation, cement maturation time, surface preparation procedures, and testing protocols.

The distribution of failure modes (Table 5) was generally consistent with the SBS findings. The absence of cohesive failure within the restorative material suggests that failure occurred predominantly at the interface or within the cement component. A significant shift in failure patterns over time was observed; adhesive failures predominated at 3 min, reflecting weak early interfacial bonding, whereas intra-cement cohesive and mixed failures increased at later time points, indicating improved interfacial stability during cement maturation. By 24 h, adhesive failures declined to their lowest level, and failure patterns predominantly towards intra-cement cohesive/mixed characters; this shift indicates that the bond strengthened over time, causing failure to occur more within the cement itself and qualitatively supporting the measured increase in SBS.

This study has several limitations. First, the in vitro design did not allow full simulation of intraoral biological and mechanical conditions, such as saliva contamination, pH fluctuations, and masticatory forces, which limits the generalisability of the findings. Second, although the application intervals of 3 and 15 min were selected to simulate a single-visit approach, all specimens were stored for 24 h after restoration placement before SBS testing under standardized conditions. Therefore, the present findings reflect the bond strength of an interface that was restored at an early stage but allowed to mature for 24 h before testing, rather than its immediate resistance to functional loading. This factor should be considered when interpreting the results in the context of single-visit clinical protocols. Third, the 3D-printed resin blocks used for specimen standardization do not reproduce the hydrophilic tubular structure of natural dentine or pulp fluid dynamics, which may influence the early maturation of CSCs, and the behaviour of adhesives on these surfaces may differ from clinical conditions. Fourth, because only one adhesive system (Clearfil SE Bond 2) was evaluated, the findings of the present study cannot be directly generalised to other bonding strategies, including universal and total-etch adhesive systems. Furthermore, the study focused on physical bond strength measurements and topographical evaluations; however, the absence of chemical interface analyses, such as Fourier-transform infrared (FTIR) or Raman spectroscopy, means that the proposed chemical interaction between the bioactive materials and CSCs remains hypothetical and requires further investigation. Finally, because the evaluation was limited to 3, 15 min, and 24 h time points, later time points such as 6 to 12 h or 7 days were not assessed; therefore, the full spectrum of maturation kinetics could not be comprehensively evaluated.

5. Conclusions

Within the limitations of this in vitro study, setting time, the type of CSC, and the type of restorative material significantly influenced the SBS. Across all CSC–restorative material combinations, SBS increased as the waiting period extended, with the lowest values observed at 3 min and the highest values at 24 h. Overall, Biodentine exhibited higher SBS, whereas NeoPUTTY was associated with lower values. Among the restorative materials, ACTIVA Kids BioACTIVE Restorative exhibited the highest SBS, whereas Dyract XP showed significantly lower performance, particularly on NeoPUTTY and NeoMTA 2 at 24 h. Failure mode analysis demonstrated a predominance of adhesive failures at early time points, followed by a shift toward intra-cement cohesive and mixed failures over time, supporting the progressive improvement of interfacial stability during CSC maturation. Clinically, delaying restoration until a later maturation stage may be advantageous whenever possible, and the use of restorative materials with higher bonding capacity to CSCs may improve outcomes. Future studies should investigate the early interfacial bonding behaviour of moisture-dependent premixed bioceramics using clinically relevant experimental models, such as dentin-disc systems with simulated pulpal pressure, and evaluate whether delayed restoration remains advantageous under such conditions.

Availability of data and materials

The datasets generated and/or analysed during the current study are available from the corresponding author upon reasonable request.

Author contributions

HEK—performed the experimental procedures. İHÇ—performed statistical analysis and interpreted the data; critically revised the manuscript. İHÇ and HEK—conceived the idea and designed the study; drafted the manuscript. Both authors revised and approved the final version of the manuscript.

Ethics approval and consent to participate

Ethical approval for this study was granted by the Afyonkarahisar Health Sciences University Non-Interventional Scientific Research Ethics Committee (Approval No: 2025/389), which confirmed that no informed consent was required due to the absence of human subjects or biological samples.

Acknowledgment

Not applicable.

Funding

This study was supported by Afyonkarahisar Health Sciences University Scientific Research Projects Coordination Unit (Project No. 25.DUS.011).

Conflict of interest

The authors declare no conflict of interest.

References

Cohenca N, Paranjpe A, Berg J. Vital pulp therapy. Dental Clinics of North America. 2013; 57: 59–73.

[Google Scholar]

Pushpalatha C, Dhareshwar V, Sowmya SV, Augustine D, Vinothkumar TS, Renugalakshmi A, et al. Modified mineral trioxide aggregate—a versatile dental material: an insight on applications and newer advancements. Frontiers in Bioengineering and Biotechnology. 2022; 10: 941826.

[Google Scholar]

Albernaz Neves J, Bandeira Lopes L, Alves Duarte M, Mendes JJ, Pimentel T. Systematic review and meta analysis of first and second generation bioceramic materials in primary dentition pulpotomies. Scientific Reports. 2025; 15: 16939.

[Google Scholar]

Parirokh M, Torabinejad M. Mineral trioxide aggregate: a comprehensive literature review—part III: clinical applications, drawbacks, and mechanism of action. Journal of Endodontics. 2010; 36: 400–413.

[Google Scholar]

Murray PE, Hafez AA, Windsor LJ, Smith AJ, Cox CF. Comparison of pulp responses following restoration of exposed and non-exposed cavities. Journal of Dentistry. 2002; 30: 213–222.

[Google Scholar]

Arandi NZ, Thabet M. Minimal intervention in dentistry: a literature review on Biodentine as a bioactive pulp capping material. BioMed Research International. 2021; 2021: 5569313.

[Google Scholar]

Camilleri J. Staining potential of Neo MTA Plus, MTA Plus, and Biodentine used for pulpotomy procedures. Journal of Endodontics. 2015; 41: 1139–1145.

[Google Scholar]

Xavier MT, Costa AL, Caramelo FJ, Palma PJ, Ramos JC. Evaluation of the interfaces between restorative and regenerative biomaterials used in vital pulp therapy. Materials. 2021; 14: 5055.

[Google Scholar]

Hardan L, Mancino D, Bourgi R, Alvarado-Orozco A, Rodríguez-Vilchis LE, Flores-Ledesma A, et al. Bond strength of adhesive systems to calcium silicate-based materials: a systematic review and meta-analysis of in vitro studies. Gels. 2022; 8: 311.

[Google Scholar]

Odabaş ME, Bani M, Tirali RE. Shear bond strengths of different adhesive systems to Biodentine. The Scientific World Journal. 2013; 2013: 626103.

[Google Scholar]

Pradelle-Plasse N, Mocquot C, Semennikova K, Colon P, Grosgogeat B. Interface between calcium silicate cement and adhesive systems according to adhesive families and cement maturation. Restorative Dentistry & Endodontics. 2020; 46: e3.

[Google Scholar]

Camilleri J. Investigation of Biodentine as dentine replacement material. Journal of Dentistry. 2013; 41: 600–610.

[Google Scholar]

Nicholson JW. Polyacid-modified composite resins (“compomers”) and their use in clinical dentistry. Dental Materials. 2007; 23: 615–622.

[Google Scholar]

Maran BM, de Geus JL, Gutiérrez MF, Heintze S, Tardem C, Barceleiro MO, et al. Nanofilled/nanohybrid and hybrid resin-based composite in patients with direct restorations in posterior teeth: a systematic review and meta-analysis. Journal of Dentistry. 2020; 99: 103407.

[Google Scholar]

Radwanski M, Zmyslowska-Polakowska E, Osica K, Krasowski M, Sauro S, Hardan L, et al. Mechanical properties of modern restorative “bioactive” dental materials—an in vitro study. Scientific Reports. 2025; 15: 3552.

[Google Scholar]

Celiksoz O, Irmak O. Delayed vs. immediate placement of restorative materials over Biodentine and RetroMTA: a micro-shear bond strength study. BMC Oral Health. 2024; 24: 130.

[Google Scholar]

Palma PJ, Marques JA, Falacho RI, Vinagre A, Santos JM, Ramos JC. Does delayed restoration improve shear bond strength of different restorative protocols to calcium silicate-based cements? Materials. 2018; 11: 2216.

[Google Scholar]

Candan M, Altinay Karaca FK, Öznurhan F. Evaluation of the shear bond strength of immediate and delayed restorations of various calcium silicate-based materials with fiber-reinforced composite resin materials. Polymers. 2023; 15: 3971.

[Google Scholar]

Ergül R, Aksu S, Çalışkan S, Tüloğlu N. Shear bond strength of calcium silicate-based cements to glass ionomers. BMC Oral Health. 2024; 24: 140.

[Google Scholar]

Jamali Z, Najafpour E, Ebrahim Adhami Z, Sighari Deljavan A, Aminabadi NA, Shirazi S. Does the length of dental procedure influence children’s behavior during and after treatment? A systematic review and critical appraisal. Journal of Dental Research, Dental Clinics, Dental Prospects. 2018; 12: 68–76.

[Google Scholar]

Sano H, Ciucchi B, Matthews WG, Pashley DH. Tensile properties of mineralized and demineralized human and bovine dentin. Journal of Dental Research. 1994; 73: 1205–1211.

[Google Scholar]

Davidson CL, de Gee AJ, Feilzer A. The competition between the composite-dentin bond strength and the polymerization contraction stress. Journal of Dental Research. 1984; 63: 1396–1399.

[Google Scholar]

Camilleri J, Sorrentino F, Damidot D. Investigation of the hydration and bioactivity of radiopacified tricalcium silicate cement, Biodentine and MTA Angelus. Dental Materials. 2013; 29: 580–593.

[Google Scholar]

Palma PJ, Marques JA, Antunes M, Falacho RI, Sequeira D, Roseiro L, et al. Effect of restorative timing on shear bond strength of composite resin/calcium silicate-based cements adhesive interfaces. Clinical Oral Investigations. 2021; 25: 3131–3139.

[Google Scholar]

Alqahtani AS, Sulimany AM, Alayad AS, Alqahtani AS, Bawazir OA. Evaluation of the shear bond strength of four bioceramic materials with different restorative materials and timings. Materials. 2022; 15: 4668.

[Google Scholar]

Hursh KA, Kirkpatrick TC, Cardon JW, Brewster JA, Black SW, Himel VT, et al. Shear bond comparison between 4 bioceramic materials and dual-cure composite resin. Journal of Endodontics. 2019; 45: 1378–1383.

[Google Scholar]

Gündoğar ZU, Keskin G, Yaman Küçükersen M. Shear bond strength of biointeractive restorative materials to NeoMTA Plus and Biodentine. Polymers. 2025; 17: 3070.

[Google Scholar]

Falakaloğlu S, Yeniçeri Özata M, Plotino G. Micro-shear bond strength of different calcium silicate materials to bulk-fill composite. PeerJ. 2023; 11: e15183.

[Google Scholar]

Suharwardy Z, Jain RK, Khetarpal A, Bala A. An in-vitro study comparing the shear bond strength of a self-adhering flowable composite and a bulk-fill flowable composite to various pulp capping materials, including Neo MTA Plus, Dycal, Biodentine, and MTA. Journal of Advances in Medicine and Medical Research. 2024; 36: 1–11.

[Google Scholar]

Martínez-Sabio L, Peñate L, Arregui M, Veloso Duran A, Blanco JR, Guinot F. Comparison of shear bond strength and microleakage between Activa™ Bioactive Restorative™ and bulk-fill composites: an in vitro study. Polymers. 2023; 15: 2840.

[Google Scholar]

Cho K, Rajan G, Farrar P, Prentice L, Prusty BG. Dental resin composites: a review on materials to product realizations. Composites Part B: Engineering. 2022; 230: 109495.

[Google Scholar]

Bağ İ, Çamgöz A, Işılar B, Çalışkan S. The effect of different adhesive applications on the bond strength of new generation primary tooth restoration materials to mineral trioxide aggregate. Black Sea Journal of Health Science. 2023; 6: 690–696. (In Turkish)

[Google Scholar]

John J, Prabath Singh VP. Comparative evaluation of the shear bond strength of MTA and Biodentine to different permanent restorative materials: an in vitro study. International Journal of Prosthodontics & Restorative Dentistry. 2022; 12: 118–124.

[Google Scholar]

Tunç EŞ, Sönmez IŞ, Bayrak Ş, Eğilmez T. The evaluation of bond strength of a composite and a compomer to white mineral trioxide aggregate with two different bonding systems. Journal of Endodontics. 2008; 34: 603–605.

[Google Scholar]